VP415
Diagnostics



If the diagnostics mode and the service manual helped me in one small way, it was pointing me to the problem with the broken drive door. Error code 1, meaning the tray doesn't work, which appeared quite a while ago, should lead us to suspect modules P and R according to the service manual. I'd already swapped out module R and ruled that out, as I've described earlier, so by this point I'd replaced the VP415's P module with the one from the VP410 and this had the effect of bringing the disc tray mechanism back to life.

Perhaps it's a little uncharitable for me to say that I could have worked it out quite easily for myself with all the module-swapping I had been doing, instead of trying to rely on useless diagnostic on-screen displays and useless information in the service manual.

Anyhow, I was very pleased about getting the disc tray functioning, I must say, because I was expecting the problem to be associated with a complex mechanical fault with the drive motors or hydraulics or all that kind of guff, not a simple electronic fault repaired by changing one of the modules.



Click here to return to VP415 Diagnostics